Start Gas
Start Gas is a variant of the Start model, which combines simplicity and compact design with the client's need for a bedhead unit also equipped with medical gas outlets.

The bedhead beam's load-bearing structure is made from a combination of three extruded aluminum profiles, resulting in a modern, compact, yet functional aesthetic with rounded shapes and an absence of sharp edges. The central profile encloses, with appropriate divisions and separations, the 230V electrical wiring for powering sockets, buttons, and switches, as well as the low-voltage wiring for data, telephone, call systems, alarms, and diagnostics, the lighting system management board, DIN-rail terminal blocks, and the general ground node. The piping and connections for medical gas outlets are separated by watertight partitions. The upper and lower profiles house the LED lighting systems, both ambient/nighttime and examination/reading. On the outside, the electrical components—supports, plates, call systems, voice, and equipotential sockets—are located at the front.
The in-house lighting system allows for indirect lighting via the upper LED bars from 4000 to 8000 real lumens (not nominal) available in 3000/4000/5000°K color temperatures, while the upper night light is managed by lowering the indirect light percentage to preset levels that the customer can easily modify according to their needs by following simple instructions.
For direct light for examination and reading, small LED modules are used, located in the lower part of the bedhead, which still maintain a light level of 1500 - 3000 real lumens for each individual module, always in the colour temperatures of 3000/4000/5000° K.
The polycarbonate screens covering the LED systems are thin and linear, allowing for greater wear resistance with less maintenance while also providing a high-performance lighting system. Furthermore, they are recessed into the aluminum profiles to create a smooth surface that reduces bacterial buildup, making cleaning and sanitizing easier for medical staff, and enhancing the finished product's design.

FABBRICANTE
UDI
N° Reg. Ministero Della Salute
Grado di Protezione
Configurazioni
Fissaggio
Posizionamento
Componenti Aggiuntivi
Materiale
Sistema di Illuminazione
Tipologia di Illuminatore
Lomar srl
80595716000810
1841952 – 2771299
IP40
for one or more beds
on the wall
horizontal
IV hook - accessory holder bar - IV pole
extruded aluminum alloy EN AW-6060
LED
LED strip in extruded aluminum including cable and connector and opal and satin lens
Flusso luminoso luce indiretta
Flusso luminoso luce diretta
Flusso luminoso luce notturna
Regolazione delle Luci
Ciclo Circadiano
Sicurezza fotobiologica sorgenti led
Classe di Isolamento
Marcatura
Classe di Rischio
from 1300 to 3000 lumens with regulation and on-off switch or 4-level step switch
from 6 to 24 lumens with 4 adjustable settings
provided upon customer request
IP40
CE0051
Class II b
Directive 93/42 MDD and subsequent amendments.
Regulation MDR 2017/745 EU
Medical device
Certificazione 93/42
Certificazione MDR 2017/745 EU
Sezione trasversale
from 3000 to 6000 lumens with dimming and on-off switch
provided upon customer request
according to EN62741
Classificazione
A – 100 mm.
- - -
H – 290 mm.